CVD - diamond drilling and concrete cutting
investors in people
.
member of the Drilling and Sawing Association
.
CVD are Constructionline accredited
.

Double Wire Saw cuts live Sewage Pipe

Morrison at Meadowhead Irvine

A concrete tank was formed around the existing sewer pipe with the new pipe coming in beside it and was designed to accommodate the dimensions and mounting of two wiresaws (one at each end of the tank to cut out the 1200 mm. dia. pipe with a 12 mm. metal skin.)

  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
  • Wire Sawing: Image
Thumbnail panels:
Now Loading

At the existing tank end the pipe had another pipe inserted inside and this made the skin 24 mm. thick.

diversion pipes
 
cut edge of steel pipe

Another part of the design was to cast square concrete sections at each side, surrounding the pipe but not attached to the floor of the tank and incorporating a plastic pipe for wire feeding purposes on the underside.

unexpected double wall pipe
 
enexpected double skinned pipe wall

These concrete sections were put in place to support the wire to make sure that it did not snag on the 12 mm. steel and worked perfectly.

A repeat of this process took place in another tank of similar design to complete the re-routing of the sewage to the new pipe.

For more information on this project please contact John Carswell at CVD on 0845 450 1701.

cutting live sewaer to create diversion
wire saw cutting concrete section
cutting through concrete and steel pipe with diamond wire saw
flow through cut section
flow pipe
cut section with diversion in place
Clyde Valley Drilling Ltd - Coddington Crescent - Eurocentral - Motherwell - ML1 4YF - Tel: 0845 450 1701- Fax: 0845 450 1702
all images © copyright Clyde Valley Drilling Ltd 2007 (info) / sitemap